Loading...
LocationHarness
Connector
Pin
Wire
Color
Expected
Reading
ConnectorGraphic
1MainP01
7
Pink(PK)
2MainP382
Pink(PK)
lessthan
2ohms
CAUTION
OvertighteningtheharnessconnectorretainingfastenerwilldamagetheprimaryTEC
controller.
AfteryouplugconnectorP01backintotheTEC,torquetheretainingfastenerforP01to25–28
in-lbs.
Pass
Thewiringtestpassed.GotoStep9.
Fail
Thewiringtestdidnotpass.Repairorreplacethefaultywiring.GotoReturningtheMachineto
Service(page21)andfollowthestepslisted.
Step8:Testtheleakdetectoralarm.
1.Removetheleakdetectoralarmfromthemachine.
2.Benchtestusing12Vpowerononeside,andgroundontheother.Thealarmshouldsound.
PassTheleakdetectoralarmtestpassed.Beginthediagnosticprocessagain.
Fail
Theleakdetectoralarmtestdidnotpass.Replacethealarm.GotoReturningtheMachineto
Service(page21)andfollowthestepslisted.