Maintenance
Note:Determinetheleftandrightsidesofthe
machinefromthenormaloperatingposition.
Note:Downloadafreecopyoftheelectricalor
hydraulicschematicbyvisitingwww.Toro.comand
searchingforyourmachinefromtheManualslinkon
thehomepage.
RecommendedMaintenanceSchedule(s)
MaintenanceService
Interval
MaintenanceProcedure
Afterthersthour
Torquethewheel-lugnuts.
Aftertherst10hours
Torquethewheel-lugnuts.
Checktheconditionandtensionofallbelts.
Aftertherst50hours
Changetheengineoilandengine-oillter.
Beforeeachuseordaily
Checkthesafety-interlocksystem.
Checktheengine-oillevel.
Drainthewaterseparator.
Checkthetirepressure.
Checktheengine-coolantlevel.
Cleandebrisofftheradiatorandoilcooler(cleanthemmorefrequentlyindirty
conditions).
Checkthehydraulic-uidlevel.
Checkthehydrauliclinesandhosesforleaks,kinkedlines,loosemountingsupports,
wear,loosettings,weatherdeterioration,andchemicaldeterioration.
Checkthebladestoppingtime.
Cleanthemachine.
Cleanandmaintaintheseatbelt.
Every25hours
Checktheelectrolytelevel.(Ifthemachineisinstorage,checkitevery30days.)
Every50hours
Lubricateallofthebearingsandbushings.
Removetheair-cleanercoverandcleanoutthedebris.Donotremovethelter.
Every100hours
Checktheconditionandtensionofallbelts.
Every150hours
Changetheengineoilandengine-oillter.
Every200hours
Servicetheair-cleanerlter.(Morefrequentlyinextremedustyordirtyconditions)
Torquethewheel-lugnuts.
Checktheparking-brakeadjustment.
Every400hours
Inspectthefuellinesandconnections.
Replacethefuellter.
Every500hours
Greasethebearingsintherearaxle.
Every800hours
Drainandcleanthefueltank.
Ifyouarenotusingtherecommendedhydraulicuidorhaveeverlledthereservoir
withanalternativeuid,changethehydraulicuid.
Ifyouarenotusingtherecommendedhydraulicuidorhaveeverlledthereservoir
withanalternativeuid,replacethehydrauliclter(sooneriftheserviceinterval
indicatorisintheredzone).
Every1,000hours
Ifyouareusingtherecommendedhydraulicuid,replacethehydrauliclter(sooner
iftheserviceintervalindicatorisintheredzone).
Every2,000hours
Ifyouareusingtherecommendedhydraulicuid,changethehydraulicuid.
35