BeltMaintenance
Checkingthe
Alternator-BeltTension
ServiceInterval:Every100hours
1.Apply44N(10lb)offorcetothealternatorbelt,
midwaybetweenthepulleys.
2.Ifthedeectionisnot10mm(3/8inch),loosen
thealternatormountingbolts(Figure47).
g008932
Figure47
1.Mountingbolt2.Alternator
3.Increaseordecreasethealternator-belttension.
4.Tightenthemountingbolts.
5.Checkthedeectionofthebeltagaintoensure
thatthetensioniscorrect.
ControlsSystem
Maintenance
AdjustingtheControl-Lever
Neutral-InterlockSwitch
1.Stopthemachine,movethemotion-control
leverstotheNEUTRAL-LOCKposition,engagethe
parkingbrake,andremovetheignitionkey.
2.Removetheboltssecuringthefrontpaneland
removethepanel(Figure48).
g020875
Figure48
1.Bolt
2.Controlpanel
3.Loosenthe2screwssecuringtheinterlock
switch(Figure49).
48