Loading...
5.Installthefuellineontothefuellter.Slidethe
hoseclampclosetothefuelltertosecurethe
fuelline(Figure40).
ElectricalSystem
Maintenance
Important:Beforeweldingonthemachine,
disconnectthecontrollerandthenegative
cablefromthebatterytopreventdamagetothe
electricalsystem.
ElectricalSystemSafety
Disconnectthebatterybeforerepairingthe
machine.Disconnectthenegativeterminalrst
andthepositivelast.Connectthepositiveterminal
rstandthenegativelast.
Chargethebatteryinanopen,well-ventilated
area,awayfromsparksandames.Unplugthe
chargerbeforeconnectingordisconnectingthe
battery.Wearprotectiveclothinganduseinsulated
tools.
Fuses
ReplacingtheEngineFuse
1.Preparethemachineformaintenance;referto
PreparingforMachine(page25).
2.Nearthestartermotor,separatethehalvesof
thein-linefuseholderoftheenginewireharness
(Figure41).
g233945
Figure41
1.Fuse
2.Startermotor
3.Removetheopenfusefromthefuseholder.
4.Insertanewfuse(30A)intothefuseholder.
5.Assemblethehalvesofthein-linefuseholder
(Figure41).