EnteringDiagnosticMode
andCheckingtheCodes
1.TurntheignitionkeytotheSTOPposition.
2.Removethetetheredcapfromthesingle-pin
connectorandthesingle-socketconnector
(Figure54A).
3.Plugthesingle-pinconnectorintothe
single-socketconnector(Figure54B).
g029822
Figure54
4.TurnthekeytotheRUNposition.
5.Watchtheash-pattern-sequenceofthe
diagnosticlightforthefollowingsignals,then
consultthefault-codetable:
Thenumberandorderofashesineach
ash-pattern-sequence.
Theorderandlengthoftimeforeachpause
ineachash-pattern-sequence.
Note:Iftherearemultiplemachinefaultsactive,
eachfaultwillashfollowedbyalongpause.
Aftereachactivefaultshasbeendisplayed,the
faultsequencewillrepeat.Ifnoactivefaults
exist,thediagnosticlightwillashcontinuously
oncepersecond.
ResettingtheFaultCodes
1.TurntheignitionkeytotheRUNposition.
2.Removethesingle-pinconnectorfromthe
single-socketconnector(Figure55).
g342081
Figure55
3.Plugthesingle-pinconnectorintothe
single-socketconnector(Figure55).
Note:Thediagnosticlightcontinuouslyashes
oncepersecond.
ExitingDiagnosticMode
1.TurnthekeytotheOFFposition(Figure56).
g341833
Figure56
1.Ignitionkey
3.RUN/ACCESSORYposition
2.STOPposition4.STARTposition
2.Removethesingle-pinconnectorfromthe
single-socketconnector(Figure57).