CHAPTER 10 SYSTEM MODE (INTERFACE COMMANDS)
B-EP Series
10-13
10.7.3 STRIP SENSOR THRESHOLD VALUE SET COMMAND [ESC] AH, [ESC] AZ
Function Sets the sensor threshold value to switch the mode between strip and batch.
Format [ESC] AH; a [LF] [NUL]
[ESC] AZ; a [LF] [NUL]
Term a: Setting
0: Operation in conformance with the strip sensor
1: Operation in conformance with the strip sensor
2: Fixed to the batch mode
3: Fixed to the strip mode
4: Reserved
Notes (1) The set parameter value is backed up and kept until a new value is set using this
command. When the power is turned on, the backed up value is retrieved and set
(2) “0: Operation in conformance with the strip sensor” has been set as the default at
the time of shipment from the factory.
(3) When either “2: Fixed to the batch mode” or “3: Fixed to the strip mode” for
parameter “a” is selected, the printer operates in the specified mode, without
automatically switching between the batch and strip modes.
(4) Designation of “4: Reserved” is ignored.