28 / 73
Copyright © 2019 Toshiba Teli Corporation, All Rights Reserved. http://www.toshiba-teli.co.jp/en/
D4296087A
Register
address
Read
Write
AC(*)
Memory
save
Default
Register name
Description
0x0021 F29C
R/W
-
0x0
DPCEnable
Sets the activation of DPC (Defective pixel correction) function.
0x0:OFF, 0x1:ON
0x0021 F2BC
0x0
DPCNumber
Sets the number of pixels to correct.
0x0 (0) 0x100 (256)
0x0040 0000
0x0
DPCValue [X
1
]
Sets the X coordinate of defective pixel (1st)
0.4M:0x0(0)0X2CF(719)
1.6M:0x0(0)0X59F(1439)
0x0040 0004
DPCValue [Y
1
]
Sets the Y coordinate of defective pixel (1st)
0.4M:0x0(0)0X21B(539)
1.6M:0x0(0)0X437(1079)
0x0040 0008
DPCValue [X
2
]
Sets the X coordinate of defective pixel (2nd)
0.4M:0x0(0)0X2CF(719)
1.6M:0x0(0)0X59F(1439)
0x0040 000C
DPCValue [Y
2
]
Sets the Y coordinate of defective pixel (2nd)
0.4M:0x0(0)0X21B(539)
1.6M:0x0(0)0X437(1079)
0x0040 07F8
DPCValue [X
255
]
Sets the X coordinate of defective pixel (255th)
0.4M:0x0(0)0X2CF(719)
1.6M:0x0(0)0X59F(1439)
0x0040 07FC
DPCValue [Y
255
]
Sets the Y coordinate of defective pixel (255th)
0.4M:0x0(0)0X21B(539)
1.6M:0x0(0)0X437(1079)
0x0021 F31C
R/W
-
0x0
SS Enable
Sets the activation of Sequential Shutter (SS) function.
0x0:OFF,0x1:ON
0x0021 F33C
R/W
-
0x1
SS TerminateAt
Sets the number of Tables to repeat the sequence.
Min:0x1(1),Max:0x10(16)
0x0050 0040
R/W
-
0x1
SS Entry 0
Sets the UserSet number to register to the first sequence.
Min:0x1(1),Max:0xF(15)
0x0050 0044
SS Entry 1
0x0050 0048
SS Entry 2
0x0050 004C
SS Entry 3
0x0050 0078
SS Entry 15
* 0.4M : BC040M, 1.6M : BC160M
* For registers other than those mentioned above, please refer to the IIDC2 Digital Camera Control
Specification Ver.1.0.0.
*AC: In relation to Acquisition Command (address:0x002 0303C) : If [AC] marked “”, the register is set to
following procedure.
Stop image output (0x0) → register setting / write command → Start image output (0x08)