4-34 Service Manual
Fuser narrow media sensor removal
1. Remove the redrive assembly. See “Redrive assembly removal” on page 4-74.
2. Remove the screw (A) securing the narrow media sensor cover to the fuser.
3. With a thumbnail, release the catches (B) holding the sensor cover to the lower exit guide (C) in place.
Note: You may need to move the narrow media flag out of the way to remove the sensor.
4. Disconnect the fuser narrow media cable at the sensor.
5. Release the catches holding the sensor in the cover.
Note: Hold the narrow media flag out of the way to remove the sensor from the cover.