Repair information 4-75
Signature button contact assembly removal
1. Remove the print cartridge.
2. Remove the left side door. See “Left door removal” on page 4-6.
3. Remove the right cover. See “Right cover removal” on page 4-8.
4. Remove outer system board shield. See “Outer shield removal” on page 4-67.
5. Disconnect signature button cable from connector J14 on the system board.
6. On models 200/210/400/410, remove the two screws (A) securing the blower duct.
7. Remove the signature button contact assembly mounting screw (B).
8. Remove the assembly signature button contact assembly.
Note: Be sure to route the cable in the same location, as shown (C), when replacing the assembly.