Register  Function / Title  Bank  Mask  Adjustment Range  Multiplier 
135 
UNDERVOLTAGE TRIP
SELECTION
0 / 1  0080  0000: Trip disabled  (0) 
0080: Trip (during run)  (1) 
 
136 
UNDERVOLTAGE DETECT
TIME
0 / 1  FFFF 
0000 ∼ 03E8 (0.00 ∼ 10.00) 
0.01 
137 
LOW CURRENT DETECT
SELECTION
0 / 1  0008  0000: Trip disabled  (0) 
0008: Trip on detection  (1) 
 
138 
LOW CURRENT DETECT
LEVEL
0 / 1  00FF 
0000 ∼ 0064 (0 ∼ 100) 
1 
139 
LOW CURRENT DETECTION
TIME
0 / 1  00FF 
0000 ∼ 00FF (0 ∼ 255) 
1 
140 
OUTPUT SHORT-CIRCUIT
DETECTION SELECT
0 / 1  0003  0000:  Standard motor  (0) 
0001: High-speed motor  (1) 
0002: Positioning use (standard 
motor) (2) 
0003: Positioning use (high-speed 
motor) (3) 
 
141 
OVERTORQUE TRIP
SELECTION
0 / 1  0040  0000: Trip disabled  (0) 
0040: Trip enabled  (1) 
 
142 
OVERTORQUE TRIP LEVEL
0 / 1  00FF 
0000 ∼ 00C8 (0 ∼ 200) 
1 
143 
FAULT TRIP EEPROM
SAVE ENABLE
0 / 1  0002  0000: Data cleared when  powered 
OFF (0) 
0002: Data retained when powered 
OFF (1) 
 
144 
COOLING FAN CONTROL
SELECTION
0 / 1  0004  0000: Automatic (temperature 
detection) (0) 
0004: Always ON  (1) 
 
145 
CUMULATIVE RUN TIMER
ALARM SETTING
0 / 1  FFFF 
0000 ∼ C34B (0.00 ∼ 999.90) 
0.02