56
LCD Display Message Data
(Hex)
Explanation
CURRENT DETECT ERROR
(PRESS CLEAR)
××1A
Output current detection circuit error
OPTION PCB ERROR
(PRESS CLEAR)
××1B
Option PCB error
OPTION ROM ERROR
××1C
Option ROM error
LOW CURRENT TRIP
(PRESS CLEAR)
××1D
Low current
UNDERVOLTAGE TRIP
(PRESS CLEAR)
××1E
Main circuit undervoltage
××1F
Unused
OVERTORQUE TRIP
(PRESS CLEAR)
××20
Overtorque
EARTH FAULT (SOFT)
(PRESS CLEAR)
××21
Earth fault (software)
EARTH FAULT (HARD)
(PRESS CLEAR)
××22
Earth fault (hardware)
OPEN FUSE TRIP
(PRESS CLEAR)
××23
Open fuse
DBR OVERCURRENT TRIP
(PRESS CLEAR)
××24
Dynamic braking resistor overcurrent
DC OVERCURRENT (ACC)
(PRESS CLEAR)
××25
Overcurrent in DC section during acceleration
DC OVERCURRENT (DEC)
(PRESS CLEAR)
××26
Overcurrent in DC section during deceleration
DC OVERCURRENT (RUN)
(PRESS CLEAR)
××27
Overcurrent in DC section during constant-speed run
AUTO-TUNING ERROR
(PRESS CLEAR)
××28
Auto-tuning error
INV TYPEFORM ERROR
(PRESS READ/WRITE)
××29
Inverter typeform error