11-3-6.Fan Motor
1) Perform the step of detachment in 11-3-2.
Front Cabinet.
2) Remove the flange nut securing the fan motor
and the propeller fan.
The flange nut is loosened by turning it
clockwise. (To tighten the flange nut, turn it
counter clockwise.)
3) Remove the propeller fan.
4) Disconnect the fan motor connector from the
inverter.
5) Remove the screws (ST1TØ4 × 20L 2 pcs.)
while holding the fan motor by hand to prevent
it from falling.
NOTE
When attaching the fan motor, tighten the flange nut to
a tightening torque of 4.9N·m (50kgf·cm).
11-3-7.Reactor
1) Perform the step of detachment in 11-3-2.
Front Cabinet and all the steps in 11-3-3.
Control Board Assembly.
2) Remove the screw (ST1TØ4 × 8L 4 pcs.) fixing
the reactor.
REQUIREMENT
After replacement, connect the lead wire connector
and check whether the connector is coupled
incompletely.
11-3-8.Compressor Assembly
1) Perform the step of detachment in 11-3-2.
Front Cabinet and all the steps in 11-3-3.
Control Board Assembly, 11-3-4.Outdoor
Unit Control P.C. Board and 11-3-5.Side
Cabinet.
Hook the claw
to the bottom plate.
B
D
(13, 16, 18)
Detail A Detail B
Detail C (07, 10) Detail D (13, 16, 18
)
Propeller fan
Fan motor
Flange nut
Reactor
+00A08-010_01EN_SVM_HighWallHeatPump.book Page 105 Wednesday, March 4, 2009 11:22 AM