44
Toshiba
8-12.Air Purifying Control
8-12-1.Purpose
This function generates negative ion while cleaning the
air in the room.
The air purifying control function is to alert the user that
something is wrong in the ionizing or air purifying
operation.
If air purifier-ON signal is received while the air
conditioner stops, the air purifier starts operation, and
if it is received while the air conditioner operates, the air
conditioner and the air purifier start operation.
The air ion generator operates linked with the air
purifying operation.
NOTE
When the previous operation was the operation of air
conditioner + air purifier, an operation of air conditioner
+ air purifier starts by pushing AC button on the remote
controller.
(Operation of air conditioner + air purifier is stored in
memory.)
*1 Fan speed at Fan Auto mode.
8-12-2.Description
Error is determined to have occurred (indicated by the
PURE indicator (Orange))in the following two cases.
1) When the panel switch has been set to OFF by
the opening of the air inlet grill, etc.
2) When an abnormal discharge caused by a
symptom such as the build-up of dirt has been
detected while the air purifier is ON.
NOTE
The above case 1) or 2) is deemed to have occurred
when the action concerned continues for more than
one second
Operation button
PURE button Air conditionerPresent status
Stop
Air purifier only
Air conditioner
Joint use of AC and air purifier
Air purifier AC operation*
Stop (All) AC + Air purifier
All stop
All stop
AC + Air purifier
AC operation
Louver
Swing is available
Fan speed *1
Air purifying operation Cooling position
AUTO, L, L+, M, M+, H
AC + Air purifying operation Follows to AC operation Follows to AC operation
Sending air purifier-ON
Operation indicator ON
Fan ON
Air purifier ON
Air purifying operation
PURE indicator ON
Louver Open
memory position (Cooling)
Air conditioner +
air purifier operation
Sending air purifier-OFF
[2] Air conditioner operates[1] Air conditioner stops
*1
*2
[1],[2]
PURE indicator ON
Moving panel Open
Air purifier ON
[3],[4]
Operation indicator OFF
PURE indicator OFF
PURE indicator OFF
Air purifier OFF
Louver close
All stop
Air purifier OFF
[3] Air purifier operates [4] Air conditioner +
Air Purifier operation
Fan OFF
Air conditioner operates
Fan speed
level
WC
(WF)*
W7
(WA)*
W5
(W7)*
W2 (W3)*
80
15
30
min
*( ): Hi Power