High Wall, Heat Pump Type
Service Manual
26
Toshiba
5 SPECIFICATIONS OF ELECTRICAL PARTS
5-1. Indoor Unit
RAS-07PKVP-E, RAS-10PKVP-E, RAS-13PKVP-E, RAS-16PKVP-E, RAS-18PKVP-E
RAS-07PKVP-ND, RAS-10PKVP-ND, RAS-13PKVP-ND, RAS-16PKVP-ND, RAS-18PKVP-ND
5-2. Outdoor Unit
RAS-07PAVP-E, RAS-10PAVP-E, RAS-13PAVP-E, RAS-16PAVP-E, RAS-18PAVP-E
RAS-07PAVP-ND, RAS-10PAVP-ND, RAS-13PAVP-ND, RAS-16PAVP-ND, RAS-18PAVP-ND
No. Parts name Type Specifications
1
Fan motor (for Indoor Unit)
E:ICF-340-30-4
ND:ICF-340-30-4A
DC280–340V, 30W
2
Room temp. sensor (TA-sensor) ( – ) 10kΩ at 25°C
3
Heat exchanger temp. sensor (TC-sensor) ( – ) 10kΩ at 25°C
4
Heat exchanger temp. sensor (TCj-sensor) ( – ) 10kΩ at 25°C
5
Humidity sensor C7-M3R-TC2 31kΩ 60%RH
6
Louver motor (right, left, Horizontal) MP24Z3N Output (Rated) 1W, 16 poles, DC12V
7
Louver motor (Moving panel) MP24Z4N Output (Rated) 1W, 16 poles, DC12V
No. Parts name Model name Rating
1
Reactor CH-57 L = 10mH, 16A
2
Fan motor (for Outdoor Unit) ICF-140-43-4R DC140V, 43W
3
Suction temp. sensor (TS sensor) (Inverter attached) 10kΩ (25°C)
4
Discharge temp. sensor (TD sensor) (Inverter attached) 1,905kΩ (120°C)
5
Outside air temp. sensor (TO sensor) (Inverter attached) 10kΩ (25°C)
6
Heat exchanger temp. sensor (TE sensor) (Inverter attached) 10kΩ (25°C)
7
Terminal block (6P) JXO-6B 20A, AC250V
8
Compressor DA111A1FD-21F 3-phases 4 poses 750W
9
Coil for P.M.V. C12A-80A DC12V
10
Coil for 4-way valve (Cooling/heating switching) VHV-01AZ535A1 DC12V
11
Coil for 4-way valve (Comp. cylinder switching) VHV-01AZ535B1 DC12V
12
Cord heater assembly (-ND model only) CSC-2 AC230V, 75W
13
Heater fuse assembly (-ND model only) — AC250V, 3.15A
+00A08-010_01EN_SVM_HighWallHeatPump.book Page 26 Wednesday, March 4, 2009 11:22 AM