10-5.Judgment by Flashing LED of Indoor Unit
While the indoor unit monitors the operation status of the air conditioner, if the protective circuit operates, the
contents of self-diagnosis are displayed with block on the indoor unit indication section.
Table 10-5-1
NOTE
The contents of items B and C and a part of item E are displayed when air conditioner operates.
When item B and C, and item B and a part of item E occur concurrently, priority is given to the block of item B.
The check codes can be confirmed on the remote controller for servicing.
Item Check code Block display Description for self-diagnosis
A
OPERATION (Green)
Flashing display (1 Hz)
Power failure (when power is ON)
B
OPERATION (Green)
Flashing display (5 Hz)
Protective circuit operation for indoor P.C. board
C
OPERATION (Green)
TIMER (Orange)
Flashing display (5 Hz)
Protective circuit operation for connecting cable
and serial signal system
D
OPERATION (Green)
Flashing display (5 Hz)
Protective circuit operation for outdoor P.C. board
E
OPERATION (Green)
TIMER (Orange)
Flashing display (5 Hz)
Protective circuit operation for others
(including compressor)
Indoor indication
lamp flashes.
Which lamp
does flash?