High Wall, Heat Pump Type
Service Manual
35
Toshiba
Table 8-3-1 Indoor fan air flow rate (Cooling,
Dry)
* The fan speed broadly varies due to position of the
louver, etc.
The described value indicates one under condition of
inclining downward blowing.
1) When setting the fan speed to L, L+, M, M+ or
H on the remote controller, the operation is
performed with the constant speed shown in
Fig. 1.
2) When the fan speed mode is manual and
TA<22°C and the compressor stops, the fan
speed is controlled from W2 (20 seconds) to
0rpm (40 seconds).
3) When setting the fan speed to AUTO on the
remote controller, revolution of the fan motor is
controlled to the fan speed level shown in Fig.
2 and Table 8-3-1 according to the setup
temperature, room temperature, and heat
exchanger temperature.
4) When the fan speed mode is AUTO and the
compressor stops, the fan speed is controlled
from W2 (20 seconds) to 0 rpm (40 seconds).
Fan speed
level
RAS-07PKVP-E
RAS-07PKVP-ND
RAS-10PKVP-E
RAS-10PKVP-ND
RAS-13PKVP-E
RAS-13PKVP-ND
Fan
speed
(rpm)
Air flow
rate
(m
3
/h)
Fan
speed
(rpm)
Air flow
rate
(m
3
/h)
Fan
speed
(rpm)
Air flow
rate
(m
3
/h)
WF 1170 645 1200 665 1300 740
WE UH 1170 645 1200 665 1300 740
WD H 1120 610 1140 625 1240 695
WC M+ 1060 570 1080 580 1180 655
WB 1050 560 1080 580 1110 605
WA M 900 455 930 475 960 495
W9 900 455 930 475 960 495
W8 L+ 820 395 840 410 860 425
W7 L 670 290 690 305 710 320
W6 L– 670 290 670 290 670 290
W5 UL 600 240 600 240 600 240
W4 550 205 550 205 550 205
W3 SUL 500 170 500 170 500 170
W2 500 170 500 170 500 170
W1 420 110 420 110 420 110
Fan speed
level
RAS-16PKVP-E
RAS-16PKVP-ND
RAS-18PKVP-E
RAS-18PKVP-ND
Fan
speed
(rpm)
Air flow
rate
(m
3
/h)
Fan
speed
(rpm)
Air flow
rate
(m
3
/h)
WF 1370 790 1450 845
WE UH 1370 790 1450 845
WD H 1310 745 1390 805
WC M+ 1250 705 1330 760
WB 1160 640 1220 680
WA M 1010 530 1070 575
W9 1010 530 1070 575
W8 L+ 930 475 980 510
W7 L 780 370 830 405
W6 L– 670 290 700 310
W5 UL 600 240 600 240
W4 550 205 550 205
W3 SUL 500 170 500 170
W2 500 170 500 170
W1 420 110 420 110