32
Limit maximum : Electric Power consumption
and Silent Operation (Outdoor Unit)
Notes
Notes
When the level is selected, POWER-SELECTION level flashes on remote LCD display for
3 seconds.
In case of 75% and 50% level, number “75” or “50” also flashes for 2 seconds.
Due to the reason that POWER-SELECTION function limits the maximum current,
inadequate cooling or heating capacity may occur.
While activating of Silent operation, inadequate heating (or cooling) capacity may occur.
Power-Selection ( )
This function is used when the circuit breaker is shared with other electrical appliances. It limits
the maximum current and power consumption to 100%, 75%, or 50% and can be implemented by
POWER-SELECTION. The lower percentage, the higher Saving and also longer compressor lifetime.
Silent Operation ( )
Keep outdoor unit operating silently to ensure either yourself or neighborhood will have a tight
sleep in nighttime.
By this feature, the heating capacity will be optimized to deliver such silent experience.
The silent operation can be selected from one of two purposes (Silent 1 and Silent 2).
There are three setting parameters: Standard level > Silent 1 > Silent 2
Silent 1:
Though operating silently, the Heating (or Cooling) capacity is still prioritized to ensure having
sufficient comfort inside the room.
This setting is a perfect balance between the Heating (or Cooling) capacity and the Sound level
of outdoor unit.
Silent 2:
Compromising the Heating (or Cooling) capacity to the Sound level in any circumstance where
the outdoor unit’s sound level is highly prioritized.
This setting has a purpose to reduce the maximum sound level of outdoor unit by 4 dB(A).
Power-Selection and Silent Operation (Outdoor Unit)
[100%]
SILENT#2 SILENT#1
[75%] [50%]