– 30 –
TA
(°C)
F4F5
F5
47
42
No.
6
Item
Fan speed
CODE No.
[5d]
Standard Type 1* Type 3*
selection
(Continued):
Outline of specifications
3)
* Only HM30 can not set up Type 1 and Type 3.
In cooling and heating operation, the mode changes to [UL]
if thermostat is turned off.
4) The fan speed when the thermostat is turned off during
cooling operation can be changed.
5) If TA 25°C when heating operation has started and when
defrost operation has been cleared, the air conditioner
operates with (H) mode or higher mode for 1 minute after TC
entered in E zone of cool air discharge preventive control
(Item 7).
6) In automatic cooling/heating operation, the fan speed of
(HH) is set larger than that in the standard cooling/heating
operation.
However the fan speed is
restricted in the automatic
heating operation as shown
in the following figure.
Remarks
Selection of high ceiling
type CODE No. :
[5d] or selection of high
ceiling on P.C. board
SW501
However only when
the high ceiling
selection is set to
[Standard]
0000 0001 0003
OFF/OFFSW501 (1)/(2) ON/OFF OFF/ON
Tap COOL HEAT COOL HEAT COOL HEAT
HH
H+
H
L+
L
UL
F1
F2
F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
HH
H+
H
L+
L
UL
HH
H+
H
L+
L
UL
HH
H+
H
L+
L
UL
HH
H+, H
L+
L
UL
HH
H+, H
L+
L
UL