What to do if the exterior of Toshiba Air Conditioner has peeling?
- JJoseph DavisSep 7, 2025
If the exterior of your Toshiba Air Conditioner has peeling or lifting coat, apply repair coating.

What to do if the exterior of Toshiba Air Conditioner has peeling?
If the exterior of your Toshiba Air Conditioner has peeling or lifting coat, apply repair coating.
How to clean or replace the filter of Toshiba Air Conditioner?
If the filter of your Toshiba Air Conditioner is covered with dust or dirt, wash it with water. If the filter is broken, replace it.
What to do if Toshiba RAV-HM301MUT-E has indoor unit-remote controller regular communication trouble?
If your Toshiba Air Conditioner's indoor unit-remote controller regular communication is not working and no data is received from the remote controller or network adapter, check the remote controller and network adapter.
What to do if Toshiba Air Conditioner has indoor / outdoor connecting wires issues?
If your Toshiba Air Conditioner is experiencing indoor / outdoor connecting wires issues, meaning no signal can be sent to the indoor unit, check the indoor / outdoor connecting wires.
What to do if Toshiba RAV-HM301MUT-E has duplicated indoor addresses?
If you're experiencing issues with duplicated indoor addresses on your Toshiba Air Conditioner, where the same address as the self-address was detected, reset the indoor address settings.
What to do if the remote controller setting is incorrect in Toshiba Air Conditioner?
If your Toshiba Air Conditioner's remote controller setting is incorrect, meaning the header remote controller has not been set (including two remote controllers), check the remote controller settings.
What to do if Toshiba RAV-HM301MUT-E has indoor unit-outdoor unit serial communication trouble?
If your Toshiba Air Conditioner is experiencing indoor unit-outdoor unit serial communication trouble, where there is serial communication trouble between indoor unit and outdoor unit, you should check the indoor / outdoor connecting wires.
What to do if there are duplicated header remote controllers in Toshiba Air Conditioner?
If you're encountering issues with duplicated header remote controllers on your Toshiba Air Conditioner, where two remote controllers are incorrectly set as the header in a double-remote controller setup, you should adjust the remote controller settings.
How to fix microcomputer misdiagnosis in Toshiba RAV-HM301MUT-E due to external noise?
If outer noise or power conditions are causing microcomputer misdiagnosis in your Toshiba Air Conditioner, and you've ruled out other causes, changing the cables of the remote controller to shielded cables may help, provided there is any noise source.
Why is the Toshiba Air Conditioner indoor fan not operating?
The indoor fan of your Toshiba Air Conditioner may not be operating because the air conditioner is being controlled by the cool air discharge preventive function in “heating”. In this case, check the indoor fan operation.
| Brand | Toshiba |
|---|---|
| Model | RAV-HM301MUT-E |
| Category | Air Conditioner |
| Language | English |
External views and dimensions for RAV-HM301MUT-E indoor unit.
External views and dimensions for RAV-HM401MUT-E and RAV-HM561MUT-E(TR) indoor units.
Refrigerating cycle diagrams for single and twin types of indoor units.
Block diagram of the indoor unit controller and its connections.
Details on operation modes, temperature control, and fan speed selection.
Identification of components on the indoor unit's main circuit board.
Specifications for optional connectors on the indoor P.C. board.
Overview of troubleshooting steps and required tools.
Procedures for diagnosing and resolving various operational issues.
Method for judging trouble location using lamp indications and check codes.
Troubleshooting for issues not indicated by specific check codes.
List of indoor unit check codes, their meanings, and representative trouble positions.
Flowcharts to diagnose specific indoor unit check codes.
Procedures for replacing the indoor unit's service P.C. board.
Setup procedures for the indoor unit at the installation site.
How to perform a test run using the wired remote controller.
Procedure for setting up forced defrost using the wired remote controller.
Explanation of the LED indicators on the indoor unit's P.C. board.
How to set various functions using the remote controller.
Wiring and setting procedures for controlling units with multiple remote controllers.
How to use the monitor function to check sensor data and operation status.
Setup procedures for local site configurations and external devices.
Setup and wiring for the 1:1 model connection interface.
Procedure to set the central control address number for indoor units.
Procedures for setting line, indoor unit, and group addresses.
Details on addressing and group control configurations.
Overview of single, twin, triple, and double twin system configurations.
Examples of automatic address setup for various configurations.
Manual address setting procedures using the remote controller.
Exploded views and parts list for specific indoor unit models.