SPECIFICATIONS
Instrument
Operating Temperature Range
Battery Type
14°F to 122°F (-10°C to 50°C)
Rechargeable Li-ion (3.7V/2600mA)
Battery Life >6 hours typical
Charger Port USB Connection
Pre-Programmed Fuels Natural Gas, LPG, Light Oil, Heavy Oil,
Bituminous Coal, Coke, Butane, Wood,
Bagasse
Dimensions 150mm x 100mm x 58mm
Weight 490g
Gas Sensor Type Electrochemical field replaceable smart
sensors (O2 and CO)
Flue Temperature Probe
Construction Pistol Grip with Stainless Steel Shaft
Hose Length 2500mm
Insertion Length 200mm
'K' Type Thermocouple Accuracy +/- 0.3%, +/- 2°F (1°C)
Maximum Temperature 1472°F (800°C)
Gases
Range Resolution Accuracy
Oxygen 0-25% 0.1% +/- 0.3%
Carbon Monoxide 0-10,000 ppm 1 ppm +/- 5 ppm or 5%
Whichever is greater
Carbon Dioxide 0-25% 0.1% Calculated
CO/CO2 Ratio 0-0.999 0.001 Calculated
Combustion Efficiency 0-100% 0.1% Calculated