Trane 4TYK8536B1000AA - Unit Installation and Operating Range

Trane 4TYK8536B1000AA
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1. General
9SS-SVM001A-EM
1.4 Unit installation
1.5 Working range
1.6 Product appearance
1:1 system is the only compatible combination.
(Only one indoor unit can be connected with one outdoor unit.)
Power Supply
Operating temperature range
This air conditioner is designed for the following outdoor operating temperatures.
Storage condition
Temperature: -13~140ºF (-25~60ºC)
Humidity: 30%~80%
Working Voltage 176V ~ 253V
Voltage Imbalance
Within a 3% deviation from each voltage at the main terminal of
outdoor unit
Starting Voltage Higher than 85% of the Rated Voltage
Type Mode
Outdoor operation temperature range
[ºF (ºC)]
Maximum Minimum
DC-Inverter Split Air
Conditioner(Cooling only type)
Cooling Operation 125 (52) 5 (-15)
36K 48K/60K