Sound power levels
Discharge
Measurement conditions:
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
long) fixed to its discharge opening.
Fan Power level in dB(A), per Hz frequency band Overall power
Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
1 55 50 42 37 37 31 30 46
FWD 08 2 57 54 47 40 30 38 40 50
3 58 57 50 42 32 40 43 53
1 57 51 45 42 34 33 28 48
FWD 10 2 58 54 48 45 38 39 35 51
3 60 58 50 48 40 42 39 54
1 57 51 45 42 34 33 28 48
FWD 12 2 58 54 48 45 38 39 35 51
3 60 58 50 48 40 42 39 54
1 56 62 50 48 39 38 36 56
FWD 14 2 61 66 55 53 47 46 45 60
3 63 69 58 56 50 50 49 63
1 57 63 51 49 40 39 37 57
FWD 20 2 61 66 55 53 47 46 45 60
3 63 69 58 56 50 50 49 63
Intake
Measurement conditions:
Measurements taken at the horizontal air intake.
Fan Power level in dB(A), per Hz frequency band Overall power
Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
1 56 55 55 53 46 45 42 57
FWD 08 2 63 62 60 60 53 53 53 64
3 66 65 63 62 56 55 57 67
1 62 58 55 58 51 48 44 61
FWD 10 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
1 62 58 55 58 51 48 44 61
FWD 12 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
1 66 65 65 65 57 50 46 68
FWD 14 2 73 72 69 71 64 59 57 74
3 78 76 73 75 69 64 63 78
1 68 72 64 64 56 52 50 69
FWD 20 2 76 76 68 71 65 61 61 75
3 78 79 71 74 69 66 66 78
As a commitment to our customers, we have created a wide service network staffed with experienced factory
authorized technicians. At Trane we offer all the benefits of after sales service direct from the manufacturer and we
are committed to our mission statement to provide efficient customer care.
We would be delighted to discuss your individual requirement with you. For further information regarding Trane
maintenance agreements please contact your local TRANE sales office.
RECOMMENDED YEARLY SERVICE ROUTINE FREQUENCIES
Year Commissioning 500 / 1000 hr Visit Annual Maintenance Inspection Visit
1 X X XX
2 X XXX
3 X XXX
4 X XXX
5 X XXX
6 X XXX
7 X XXX
8 X XXX
9 X XXX
10 X XXX
+10 Every year 3 Every year
This timetable is applicable to units operating in normal conditions with an average of 4000 hours per year.
If operating conditions are abnormally severe, an individual timetable must be made for that unit.
Recommended service routine frequencies