18
System Operating Status
1. Press the NEXT key until the following screen is displayed.
The following three screens are applicable when Superheat
/
Subcool Module is installed.
Used on Units:
40-60 Ton Units with superheat/subcool module
Possible Values:
-40 to 200 F
1. Press the NEXT key until the following screen is displayed.
Used on Units:
40-60 Ton Units with superheat/subcool module
Possible Values:
Suction range 0 - 100 PSIG
Liquid range 0 - 400 PSIG
Comp Off
1. Press the NEXT key until the following screen is displayed.
Used on Units:
40-60 Ton Units with superheat/subcool module
Possible Values:
0 - 99.9 F
Comp Off
1. Press the NEXT key until the following screen is displayed.
Used on Units:
20, 25 & 30 Ton Units
Possible Values:
Open, Closed
OR
The following screen is displayed for 40 through 60 Ton units.
Used on Units:
40 Thru 60 Ton Units
Possible Values:
Open, Closed
1. Press the NEXT key until the following screen is displayed.
Used on Units:
All Units with Current Sensing Module
Possible Values:
0 - 255
1. Press the NEXT key until the following screen is displayed.
Used on Units:
All Units with Current Sensing Module
Possible Values:
0 - 255
1. Press the NEXT key until the following screen is displayed.
The following screens are displayed for 40 through 60 Ton units.
Used on Units:
40-60 Ton Units with Current Sensing Module
Possible Values:
0 - 255
1. Press the NEXT key until the following screen is displayed.
Used on Units:
40-60 Ton Units with Current Sensing Module
Possible Values:
0 - 255
1. Press the NEXT key until the following screen is displayed.
2. Pressing the NEXT key will display the beginning of
the Submenu.
3. Press the NEXT key again to advance to the following screen.
1. Press the ENTER key until the following screen is displayed.
2. Press the NEXT key to bypass this menu and advance to
"Controlling Setpoint Status Submenu"
Used on Units:
All Units
Possible Values:
CGM Evap Solution Pump Relay = On, Off
Evap Soln Flow Switch Proving = Flow, No Flow
1. Press the NEXT key until the following screen is displayed.
General System Status Submenu
Press ENTER to View Data in This Submenu
CGM Evap Solution Pump Relay: OFF
Evap Soln Flow Switch Proving: FLOW
Refrigerant Ckt 2 - Temperature Data
Suction 72.0 F Sat Liquid 97.0 F
Refrigerant Ckt 2 - Pressure Data
Suction 65 PSIG Liquid 251 PSIG
Refrigerant Circuit 2
Superheat 28.0 F Subcooling 18.0 F
Ckt 1 Liquid Line Solenoid Valve: OPEN
Ckt 2 Liquid Line Solenoid Valve: CLOSED
Compressor 1A Phase Currents - Amps
Phase A 86 Phase B 84
Compressor 1B Phase Currents - Amps
Phase A 81 Phase C 78
Compressor 2A Phase Currents - Amps
Phase B 88 Phase C 90
Compressor 2B Phase Currents - Amps
Phase A 93 Phase C 89
End of Submenu (NEXT) to Re-enter STATUS
Ckt 1 Liquid Line Solenoid Valve: OPEN

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane IntelliPak CGAF Series and is the answer not in the manual?

Trane IntelliPak CGAF Series Specifications

General IconGeneral
BrandTrane
ModelIntelliPak CGAF Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals