Records changes made to the manual, including original issue details.
Describes the manual's structure and purpose for operators.
Explains the alphanumeric model number for unit identification.
Details the information found on the unit's identification plates.
Explains warning symbols (WARNING, CAUTION) and their meanings.
Provides definitions for acronyms and abbreviations used in the manual.
Describes how the Human Interface displays unit status and modes.
Explains the function of each key on the Human Interface keypad.
Details keys used for changing values and navigating data.
Explains keys like AUTO, STOP, CUSTOM for unit control.
Illustrates the different status screens shown on the Human Interface.
Lists adjustable functions and their default factory settings.
Outlines screens requiring passwords for access or modification.
Used to view operating conditions, component status, and setpoints.
Provides access to detailed data regarding compressor operation.
Displays the status (On/Off/Locked) of compressor control relays.
Shows temperature and pressure data for refrigerant circuit 1.
Shows temperature and pressure data for refrigerant circuit 2.
Displays the measured current for each compressor phase.
Shows the source and value of active setpoints.
Displays readings from various temperature sensors.
Shows status of miscellaneous inputs like Ice Build Command.
Displays status and assignments for GBAS 0-5VDC module.
Entry point for configuring unit parameters and functions.
Configures fundamental unit operations and parameters.
Sets parameters for reducing cooling capacity based on demand.
Configures compressor sequencing for optimal operation.
Sets delay before turning off the evaporator solution pump.
Enables/disables compressor operation at low ambient temperatures.
Configures settings related to the ice building process.
Configures parameters for controlling head pressure.
Assigns inputs and outputs for the GBAS 0-5VDC module.
Defines the function of GBAS 0-5VDC binary outputs.
Assigns inputs and outputs for the GBAS 0-10VDC module.
Assigns diagnostic functions to CGM alarm outputs.
Defines characteristics for various actuators and sensors.
Adjusts parameters for comfort and process cooling algorithms.
Configures setpoints and gains for comfort cooling mode.
Sets the primary leaving solution temperature setpoint.
Configures the setpoint for terminating ice building.
Sets the temperature below which the solution pump will stop.
Sets the temperature threshold for heat tape activation.
Sets the limit for compressor operation during hot start.
Sets temperature for overriding solution pump operation at low ambient.
Sets temperature to prevent compressor operation at low ambient.
Selects the source for the leaving solution setpoint.
Selects the source for the ice building terminate setpoint.
Selects the source for the hot start load limit setpoint.
Selects the source for the capacity limit setpoint.
Configures unit parameters based on model number digits.
Displays the software version for various unit modules.
Accesses operating parameters for service tests and component control.
Manually control and test unit components like pumps, fans, and relays.
Initiates and manages service tests, displays test active status.
Provides access to active and historical diagnostic fault codes.
Procedures for resetting diagnostics and password entry.
Steps for resetting manual and auto diagnostics.
Explains different categories of unit failure modes.
Identifies and troubleshoots issues with module communication.
Details diagnostics for sensors (ICS, OA, Zone), pumpdown, contactors, etc.
Lists Analog Inputs, Outputs, and Binary I/O for the CGM.
Lists Analog Inputs, Outputs, and Binary I/O for the CSM.
Lists Analog Inputs, Outputs, and Binary I/O for GBAS 0-5VDC.
Lists Analog Inputs, Outputs, and Binary I/O for GBAS 0-10VDC.
Lists I/O for the Human Interface module.
Lists Analog Inputs, Outputs, and Binary I/O for MCM.
Lists Analog Inputs, Outputs, and Binary I/O for SCM.
Lists Analog Inputs, Outputs, and Binary I/O for the SSM.
Lists Analog Inputs, Outputs, and Binary I/O for the TCI module.
Lists Analog Inputs, Outputs, and Binary I/O for the LCI module.