i-HPV5 Inverter air/water heat pumps with axial fan
30

-





-




11. RESIDUAL RISK



Danger  Residual risk

Operator User
Transport phase




Mechanical: crushing caused by
the possible instability of the unit
during handling
The procedures for correct unit
handling and installaon are
indicated on the user-installer
manual under chapter 5, with in-
dicaon of the center of gravity,
of the liing points and equip-
ment. Protecon devices use is
also recommended as required
by current regulaons.
Failure by the installer to comply
with the installaon procedures.
X X
Mechanical: crushing caused by
the possible instability of the unit.
The procedures for proper unit
installaon are indicated on
user-installer manual under
chapter 5.
Failure by the installer to comply
with the installaon procedures.
X X
Mechanical: Cung / seconing
/ shearing caused by the fan not
protected against accidental
contacts
The user-installer manual under
chapter 9 contains specic warn-
ings, also relang to the roune
maintenance phases.
Removal of the protecve grille
by the user or maintenance
technician.
X X
Entanglement caused by the fan
not protected against accidental
contacts
The user-installer manual under
chapter 9 contains specic warn-
ings, also relang to the roune
maintenance phases.
Removal of the protecon grid
by the user or maintenance
technician.
X X
Mechanical: cung / abrasion
due to contact with the heat
exchange coil
The user-installer manual under
chapter 9 contains specic
warnings to be taken into consid-
eraon when working near the
baery.
Failure to observe the warnings
in the manual and on the label.
X X
Mechanical: slipping / falling
caused by ice / water near the
unit as a result of water leaks
In the user-installer manual
under paragraph 5.8 is recom-
mended to pay aenon to the
conveyance of the safety valve
and in paragraph 5.4 there are
indicaons regarding the surface
on which the unit rests. During
maintenance, the use of PPE and
the possible removal of all water
residues near the machine aer
intervenon is recommended.
Failure to comply with the in-
strucons given in the manual.
X X