i-HPV5 Inverter air/water heat pumps with axial fan
33
Danger Residual risk
Operator User
Transport phase
Generated by unit use environ-
ment: lightning that can poten-
ally hit the unit
In the user-installer manual un-
der chapter 9 it is recommended
to carry out maintenance only in
weather condions suitable for
the operaons envisaged. It is
also indicated that the installaon
site must be suciently far from
lightning rods or objects that
could aract the lightning (par.
5.3). The unit must be electri-
cally connected to a system that
complies with the regulaons in
force.
Failure to comply with the in-
strucons given in the manual.
X X
Generated by unit use environ-
ment: electromagnec distur-
bances caused by interference
between devices placed near the
machine and the machine itself.
In the user-installer manual
under paragraph 5.9 is recom-
mended to power the unit via a
dedicated line and protecons. It
is also recommended to use an
independent cable duct in order
to remove the possibility of inter-
acon with other devices.
Failure to comply with the
recommendaons regarding the
electrical system.
X
Generated by unit use environ-
ment: possibility of breakage of
components / supports caused by
corrosion and oxidaon.
The user-installer manual under
chapter 9 contains specic
warnings on maintenance and
cleaning to be carried out on the
surfaces of the sheets and heat
exchange coils. The technical
bullen provides advice on the
treatments to choose based on
the environmental condions.
Failure to comply with cleaning
and maintenance and / or incor-
rect assessment of the atmo-
spheric agents that characterize
the installaon site.
X X
Generated by the operang
environment of the machine: slip-
ping/falling caused by ice/snow
on the base of the unit.
In the user-installer manual
in secon 4.2 the use of per-
sonal protecve equipment is
recommended. In the user-in-
staller manual in chapter 9 it is
recommended that maintenance
should only be carried out in
weather condions suitable for
the intended operaons.
Failure to comply with cleaning
and maintenance and / or incor-
rect assessment of the atmo-
spheric agents that characterize
the installaon site.
X
Generated by the operang en-
vironment of the machine: Heat
stroke due to high temperatures
inside the machine if it is hot, the
unit is working in a chiller and is
located in a parcularly sunny
area.
In the user-installer manual
in secon 4.2 the use of per-
sonal protecve equipment is
recommended. In the user-in-
staller manual in chapter 9 it is
recommended that maintenance
should only be carried out in
weather condions suitable for
the intended operaons.
Failure to comply with cleaning
and maintenance and / or incor-
rect assessment of the atmo-
spheric agents that characterize
the installaon site.
X