Digit 25 - Free Cooling
X = No Free Cooling
F = Total Free-Cooling Direct
G = Partial Free-cooling Direct
H = Total Free Cooling Glycol Free
J = Partial Free Cooling Glycol Free
Digit 26 – Disconnect switch
F = With Fuse
B = With circuit breaker
Digit 27 – Under/Over Voltage
X = None
1 = Included
2 = Included with ground fault protection
Digit 28 – Human Interface language
C = Spanish
D = German
E = English
F = French
H = Dutch
I = Italian
M = Swedish
P = Polish
R = Russian
T = Czech
U = Greek
V = Portuguese
2 = Romanian
6 = Hungarian
8 = Turkish
Digit 29 – Smart com protocol
X = None
B = Bacnet interface
M = Modbus interface
L = LonTalk interface
Digit 30 – Communication customer
X = None
A = External set point & capacity outputs
Digit 31 – Flow switch
X = None
F = Field installed fl ow switch
Digit 32 – Electrical Panel Protection
X = Enclosure with deadfront protection
1 = Enclosure with IP 20 internal protection
Digit 33 – Master Slave
X = Open for Future Use
Digit 34 – Unit User Interface
L = Standard, Local UI supplied (TD7)
Digit 35 – Energy meter
X = No energy meter
M = Energy meter installed
Digit 36 – Open for future use = X
Digit 37 – Variable Primary Flow
X = None
F = Constant Speed Pump -AFD Adjustment
P = Variable Speed Pump - Constant delta P
T = Variable Speed Pump - Constant delta T
Digit 38 – Open for future use = X
Digit 39 – Open for future use = X
Digit 40 – Power socket
X = None
P = Included (230V - 100W)
Digit 41 – Factory tests
X = No fi nal performances test
B = Visual inspection with customer
E = Performance test w/o customer
Digit 42 – Installation accessory
X = None
1 = Neoprene Isolators
4 = Neoprene pads
Digit 43 – Literature language
B = Bulgarian
C = Spanish
D = German
E = English
F = French
H = Dutch
I = Italian
K = Finnish
L = Danish
M = Swedish
N = Norvegian
P = Polish
R = Russian
T = Czech
U = Greek
V = Portuguese
Z = Slovenian
2 = Romanian
3 = Serbian
4 = Slovak
5 = Croatian
6 = Hungarian
8 = Turkish
Digit 44 – Shipping package
X = Standard protection
A = Containerization package
Digit 45 – Refrigerant
0 = R134a Factory pre-charge
1 = R134a Factory full refrigerant charge
2 = R513A Factory pre-charge
3 = R513A Factory full refrigerant charge
L = Factory Nitrogen Charge for R1234ze unit
M = Factory Nitrogen Charge for R513A unit
N = Factory Nitrogen Charge for R134a unit
Y = R1234ze Factory pre-charge
Z = R1234ze Factory full refrigerant charge
Digit 46 – Oil Cooler (Only applicable to XSE/XSS)
X = No
C = Yes
For SE/HE/XE/HSS/HSE, this digit is always = X
Digit 47 – Expansion valve (Only applicable to XSE/XSS)
L = Large valve
U = Undersized valve (Only for XSE & XSS)
For SE/HE/XE/HSS/HSE, this digit is always = X
Digit 48 – Design special
X = none
S = special
Unit Model Number Description