46
18-GJ89D1-1F-EN
TAMXB0B30 AIRFLOW PERFORMANCE CONSTANT CFM MODE / CONSTANT TORQUE MODE
OUTDOOR
MULTIPLIER
(TONS)
COOLING
AIRFLOW
SETTING
AIRFLOW
POWER
EXTERNAL STATIC PRESSURE (Constant CFM / Constant Torque)
HEATING
AIRFLOW
SETTING
AIRFLOW
POWER
EXTERNAL STATIC PRESSURE
0.1 0.3 0.5 0.7 0.9 0.1 0.3 0.5 0.7 0.9
1.5 tons
290
CFM/ton
CFM
Watts
492 / 581
22 / 30
442 / 397
45 / 41
408 / NA
71/ NA
353 / NA
98 / NA
221 / NA
129 / NA
290
CFM/ton
CFM
Watts
485
21
437
44
393
69
349
97
300
130
350
CFM/ton
CFM
Watts
576 / 664
30 / 40
553 / 515
58 / 54
527 / NA
87 / NA
493 / NA
117 / NA
472 / NA
150 / NA
350
CFM/ton
CFM
Watts
574
29
545
56
517
85
489
115
457
146
400
CFM/ton
CFM
Watts
644 / 730
38 / 49
633 / 598
70 / 65
612 / 403
102 / 72
590 / NA
134 / NA
563 / NA
167 / NA
400
CFM/ton
CFM
Watts
643
37
624
67
605
99
583
132
559
165
450
CFM/ton
CFM
Watts
711 / 794
47 / 60
708 / 673
83 / 77
691 / 510
118 / 86
678 / NA
154 / NA
656 / NA
189 / NA
450
CFM/ton
CFM
Watts
709
45
698
80
684
115
669
151
649
186
2 tons †
290
CFM/ton
CFM
Watts
627 / 713
36 / 47
611 / 576
66 / 62
589 / 369
98 / 68
568 / NA
130 / NA
542 / NA
163 / NA
290
CFM/ton
CFM
Watts
625
35
603
64
582
95
559
127
533
160
350
CFM/ton
CFM
Watts
734 / 815
51/ 64
730 / 698
87 / 82
717 / 541
124 / 91
705 / NA
161 / NA
684 / NA
197 / NA
350
CFM/ton
CFM
Watts
731
49
722
84
710
120
696
157
677
193
400 †
CFM/ton
CFM
Watts
822 / 898
66 / 81
824 / 792
107 / 101
817 / 657
149 / 112
811 / NA
191 / NA
797 / NA
231 / NA
400
(a)
CFM/ton
CFM
Watts
817
63
815
103
811
145
801
186
788
226
450
CFM/ton
CFM
Watts
910 / 982
85 / 102
916 / 884
131 / 123
916 / 763
178 / 136
914 / 610
226 / 140
904 / NA
270 / NA
450
CFM/ton
CFM
Watts
902
80
907
126
908
172
904
219
895
263
2.5 tons
290
CFM/ton
CFM
Watts
755 / 860
54 / 73
753 / 749
92 / 91
742 / 606
130 / 102
732 / 397
168 / 104
712 / NA
205 / NA
290
CFM/ton
CFM
Watts
753
52
745
88
735
126
723
164
706
201
350
CFM/ton
CFM
Watts
887 / 985
80 / 102
893 / 887
125 / 124
891 / 767
170 / 137
888 / 614
217 / 141
876 / NA
260 / NA
350
CFM/ton
CFM
Watts
881
75
884
120
884
165
879
210
868
253
400
CFM/ton
CFM
Watts
998 / 1094
107 / 134
1010 / 1003
160 / 158
1017 / 895
213 / 173
1018 / 765
266 / 179
1008 / NA
315 / NA
400
CFM/ton
CFM
Watts
989
100
1001
152
1008
205
1008
257
1000
306
450
CFM/ton
CFM
Watts
1116 / 1212
143 / 176
1135 / 1126
205 / 201
1147 / 1027
267 / 219
1148 / 911
325 / 227
1134 / NA
376 / NA
450
CFM/ton
CFM
Watts
1104
133
1124
194
1136
255
1139
314
1128
366
3 tons
290
CFM/ton
CFM
Watts
883 / 981
79 / 101
888 / 882
124 / 122
887 / 762
169 / 136
881 / 608
214 / 140
870 / NA
257 / NA
290
CFM/ton
CFM
Watts
877
74
880
118
879
164
874
208
863
252
350
CFM/ton
CFM
Watts
1043 / 1140
120 / 150
1059 / 1051
177 / 174
1068 / 947
233 / 190
1069 / 823
288 / 197
1059 / NA
339 / NA
350
CFM/ton
CFM
Watts
1034
112
1049
168
1058
224
1061
279
1053
330
400
CFM/ton
CFM
Watts
1190 / 1304
170 / 203
1214 / 1221
238 / 231
1226 / 1126
304 / 251
1223 / 1016
364 / 261
1201 / 886
414 / 261
400
CFM/ton
CFM
Watts
1177
157
1201
224
1215
291
1215
352
1198
403
450
CFM/ton
CFM
Watts
1355 / 1471
241 / 282
1376 / 1391
318 / 311
1375 / 1302
386 / 333
1353 / 1201
441 / 345
1296 / 1086
472 / 345
450
CFM/ton
CFM
Watts
1338
221
1363
299
1368
369
1350
427
1314
472
• † Factory Setting
• Status LED will blink once per 100 CFM requested. In torque mode, actual airflow may be lower.
• Torque mode will reduce airflow when static is above approximately 0.35" water
column.
• All heating modes default to Constant CFM.
• Cooling airflow values are with wet coil, no filter
TAMXB0B30 Minimum Heating Airflow Settings
MODEL NO.
BAYEAAC04BK1
BAYEAAC04LG1
BAYEAAC05BK1
BAYEAAC05LG1
BAYEAAC08BK1
BAYEAAC08LG1
BAYEAAC10BK1
BAYEAAC10LG1
BAYEAAC10LG3 BAYEABC15BK1 BAYEACB15LG3 BAYEABC20BK1
TAMXB0B30
723/808 723/1020 765/1020 680/808 765/1063 850/1105
–
WITHOUT HEAT PUMP / WITH HP — SEE AIR HANDLER NAMEPLATE
(a)
Factory heating default setting is 430 CFM/ton