Index
CNT-SVX06B-EN 73
Heat pump configuration, 20
LonTalk communication
Wiring and addressing
specifications, 9
LonTalk protocol,
see Product
description
Low-temperature detection
Diagnostics, 14, 34, 62, 64
Low-temperature detection input
1 heat/1 cool configuration, 34
Heat pump configuration, 14
M
Maintenance (filter change)
diagnostic, 62, 64
Manual output test, 58
Master/slave data sharing, 54
Morning cool-down, 28, 50
Morning warm-up, 28, 50
Mounting
Cover, 12
Diagram, 12
Location, 11
Operating environment, 11
Procedures, 12
N
National Electrical Code, 7, 8, 9
Neuron IDs
Description, 9
Location of label, 57
O
Occupancy
Switch, 35
Switches, 4, 15
Occupancy input
1 heat/1 cool configuration, 35
Heat pump configuration, 15
Occupancy modes, 1 heat/1 cool
General, 48
Occupied, 48
Occupied bypass, 49
Occupied standby, 49
Unoccupied, 49
Occupancy modes, heat pump
General, 26
Occupied, 26
Occupied bypass, 27
Occupied standby, 27
Unoccupied mode, 27
Operating environment, 11
Outdoor air damper
Operation, 30, 54
Troubleshooting, 70
Outputs,
see Binary outputs
Overriding binary outputs
1 heat/1 cool, 38
General, 58
Heat pump, 22
P
Peer-to-peer data sharing, 30, 54
Power transformers, 4, 8
Power wiring, 8
Power-up sequence, 25, 47
Pressure (abnormal) diagnostics,
16, 62, 63
Product description, 1
Protection strategies
1 heat/1 cool, 55
Heat pump, 31
R
Random start, 26, 48
Relays, 5, 21, 38
Reversing valve operation, 30
Rover service tool, 1, 9
S
Sensors
Table of options, 4
Water and duct temperature, 4
Zone temperature, 4
Sequence of operations, 1 heat/1
cool
Electric heat operation, 54
Fan operation and status, 52
Filter-maintenance timer, 55
Four-pipe operation, 53
Heating/cooling mode, 51
Morning cool-down, 50
Morning warm-up, 50
Occupancy modes, 48
Outdoor air damper operation, 54
Peer-to-peer data sharing, 54
Power-up sequence, 47
Random start, 48
Smart reset, 55
Timed override control, 50
Two-pipe operation, 53
Two-position valve operation, 53
Unit protection strategies, 55
Zone temperature control, 48
Sequence of operations, heat pump
Compressor operation, 29
Fan operation and status, 29
Filter-maintenance timer, 31
Heating/cooling mode, 29
Morning cool-down, 28
Morning warm-up, 28
Occupancy modes, 26
Outdoor air damper operation, 30
Peer-to-peer data sharing, 30
Power-up sequence, 25
Random start, 26
Reversing valve operation, 30
Smart reset, 31
Timed override control, 28
Unit protection strategies, 31
Zone temperature control, 26
Service button (pin), 57-58
Set-point failure diagnostic, 20, 63,
64
Smart reset, 31, 55
Specifications
AC power wiring, 8
Agency listing/compliance, 2
Clearances, 4
Dimensional diagram, 3
Dimensions, 2
Input/output terminal wiring, 7
LonTalk communication wiring
and addressing, 9
Storage environment, 1
Transformer s , 8
Status indicators for operation and
communication
Diagnostics, 62
General, 57
Green LEDs, 60
Manual output test, 58
Red LEDs, 60
Service button (pin), 58
Test button, 57
Yellow LEDs, 61
Storage environment, 1
Switches
Condensate overflow, 4, 15, 18,
34
Current sensing, 4, 18
Freeze protection, 4, 14, 16, 18, 34
Occupancy, 4, 15, 35
T
Temperature sensors
Table of options, 4
Water and duct, 4
Zone, 4
Termination resistors, 9
Test button, 57-58
Thermistor, 4, 19, 21, 36, 37
Timed override control
1 heat/1 cool, 50
Heat pump, 28
Transformers, 4, 8
Troubleshooting

Table of Contents

Other manuals for Trane Tracer ZN511

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane Tracer ZN511 and is the answer not in the manual?

Trane Tracer ZN511 Specifications

General IconGeneral
BrandTrane
ModelTracer ZN511
CategoryController
LanguageEnglish

Related product manuals