19
Setup Manual - Butler S2
Versions
Hardware Build Version The hardware version (read only).
Software Build Version The software version (read only).
Cluster Mode
Cluster ID Generated ID of the cluster for master/slave mode.
Cluster Size Number of engines in this cluster.
Device Mode Master or Slave n/m (n of m).
Advanced Setup
Lock Settings Checkmark, set by default, avoids changes for DMX
and RDM by chance.
BRK Length Break signal length in µs for the DMX protocol.
MAB Length Mark after break length in µs for the DMX protocol.
BRK Length RDM Break length in µs for the RDM protocol.
MAB Length RDM Mark after break length in µs for the RDM protocol.
RDM Switch Time The RDM Tx to Rx length in in µs.
BRK Length Break length for e:pix protocol (not used).
MAB Length Mark after break length for e:pix protocol (not used).
Do not modify the Advanced Settings, if you are not fully aware of the results.
Close the Network Configuration Dialogue, the changes will be transferred to the
Butler S2. You can now integrate the Butler S2 to the Programmer for DMX output
or show upload.
Execute the Device Manager dialogue of the Programmer by clicking the smart-