GDM-HST02
TEC_TM_158 | REV. B | EN 12/4/2023 Page 27 of 48
truemfg.com
Electronic Temperature Control
Electronic Temperature Control
LAE CONTROL LEGEND
Info/Set Point Manual Activation/
Up Arrow
Manual Defrost/
Down Arrow
Stand-By/
Cancel
Compressor Running
Activation of 2
nd
Parameter Set
Alarm
Appliance in Defrost
Evaporator Fan Running
DISPLAY CODES
Display Denition Display Denition
hSt
Health Safety Timer password entry
dEF
Defrost in progress
dLc
Door Lock / Unlock password entry
oFF
Controller in stand-by
Loc
Keypad state lock
do
Door open alarm
t1
Instant probe 1 temperature
hi
Appliance high temperature alarm
t2
Instant probe 2 temperature
Lo
Appliance low temperature alarm
t3
Instant probe 3 temperature
E1
Probe t1 failure
min
Minute of the real time clock
E2
Probe t2 failure
hrS
Hours of the real time clock
E3
Probe t3 failure
Stt
Start time for timed actions
hSt/dLY
Delays checking of Health Safety Timer
conditions
Edt
End time for timed actions
hSt/tSt
Testing the Health Safety Lock
thi
Maximum probe 3 temperature recorded
hLA/Loc
Health Safety Alarm / lockout active
tLo
Minimum probe 3 temperature recorded
PF
Power failure