GDM-HST02
TEC_TM_158 | REV. B | EN 12/4/2023 Page 31 of 48
truemfg.com
Electronic Temperature Control (cont.)
Clear the Health Safety Alarm or Product
Loading & Servicing Delay
NOTICE ›
Clearing the Health Safety Alarm through the
display will return the appliance to its state prior to the
alarm activation (locked or unlocked).
1. Press info to show hSt.
2. Press and hold info until the display shows 00.
DO NOT RELEASE THE BUTTON!
3. While holding info, press the up arrow until the display
shows 01.
4. Release all buttons and wait for the control to display the
current appliance temperature.
Silence the Door Open Alarm
If the door remains open for 5 minutes, the control emits a
series of beeps and the display flashes do.
To silence the alarm, shut the door or press ANY button on
the control. The display will continue to flash do until the door
closes.
LAE CONTROL LEGEND
Info/Set Point Manual Activation/
Up Arrow
Manual Defrost/
Down Arrow
Stand-By/
Cancel
Compressor Running
Activation of 2
nd
Parameter Set
Alarm
Appliance in Defrost
Evaporator Fan Running