Electronic Temperature Control (cont.)
Change Defrost Intervals
The defrost interval is the duration between defrost cycles,
NOTICE ›
The defrost interval can only be changed if the
defrost mode parameter dFm is set for tim or Fro.
1. Press and hold both info and cancel until the
display shows hSt.
2. Press the up arrow until the display shows dFt.
3. Press and hold info until the display shows the current
defrost interval time. DO NOT RELEASE THE BUTTON!
4. While holding info, the up or down arrows to adjust
the setting.
5. Release all buttons and wait for the control to display the
current appliance temperature.
Change Display Readout
The display can show the temperature in either Fahrenheit or
Celsius.
Press cancel
to cycle through the display readout
options.
• °F: Fahrenheit (no decimal)
• 1°C: Celsius (0.1 precision)
• 2°C: Celsius (no decimal)
Celsius
Celsius (0.1 precision)Fahrenheit
LAE CONTROL LEGEND
Info/Set Point Manual Activation/
Up Arrow
Manual Defrost/
Down Arrow
Stand-By/
Cancel
Compressor Running
Activation of 2
nd
Parameter Set
Alarm
Appliance in Defrost
Evaporator Fan Running