Electronic Temperature Control (cont.)
Change the Set Point
Changing the set point adjusts the appliance temperature to
keep optimal product temperature.
NOTICE ›
The set point value is NOT the appliance
holding temperature. To maintain proper operation within a
safe temperature range and prevent an alarm activation, it is
recommended to only change the value by a few degrees.
1. Press and hold info until the display shows the
current set point. DO NOT RELEASE THE BUTTON!
2. While holding info, press the up or down
arrows to adjust the setting.
3. Release all buttons and wait for the control to display the
current appliance temperature.
Initiate Manual Defrost
A manual defrost clears accumulated frost and ice from the
evaporator coil. The defrost will only terminate when a specific
preset temperature or duration has been met.
Press Manual Defrost
until the display shows deF.
LAE CONTROL LEGEND
Info/Set Point Manual Activation/
Up Arrow
Manual Defrost/
Down Arrow
Stand-By/
Cancel
Compressor Running
Activation of 2
nd
Parameter Set
Alarm
Appliance in Defrost
Evaporator Fan Running