20 TROUBLESHOOTING
Issue Possible Cause(s) Resolution
F1: Blower Running
Status Bad
- Oven power interrupted.
- Blower motor not running.
- Verify wall circuit breaker is on. Reset the
breaker and then power the oven on.
- Place the oven in the state and unplug
the oven – leave for two minutes. Re-plug in
the oven, switch on the isolator/main power
supply, and press the “On/Off” soft key.
- Call Customer Support.
F2: Cook
Temperature Low
- Oven power interrupted.
- Air nozzles on the top/bottom
of the cook cavity are clogged.
- Oven door is out of alignment.
- Defective heater.
- Blower motor not running.
- Oven not fully warmed up.
- Verify wall circuit breaker is on. Reset the
breaker and then power oven back on.
- Open oven door and verify the air nozzles
on the top/bottom of the cook cavity are
clean and not clogged.
- Open and close the door several times and
verify oven door is closed.
- Reset high-limit located in the bottom left
corner of the oven rear wall. If the problem
persists, call Customer Support.
- Call Customer Support.
- Repeat warmup and allow oven to idle
for five minutes.
F3: Magnetron
Current Low
- Microwave circuit defective.
- Call Customer Support.
F4: Door Monitor
Defective
- Oven door switches are out of
order.
- Call Customer Support.
F5: Magnetron Over
Temperature
- Blockage of cool air into the
oven.
- Rear cooling fan exhaust
guard(s) clogged.
- Remove anything that may be obstructing
the flow of cool air into the oven.
- Check rear fans to see if they are free of
debris. Clean as required.
F6: EC Temp - Blockage of cool air into the
oven.
- Rear cooling fan exhaust
guard(s) clogged.
- Remove anything that may be obstructing
the flow of cool air into the oven.
- Check rear fans to see if they are free of
debris. Clean as required.