EN
UNI 30 E 17261 - 561.228 7 - USE AND OPERATION
Cap. 7 - Pag. 3/14
THIS MANUAL IS PROPERTY OF - ANY TOTAL OR PARTIAL REPRODUCTION IS STRICTLY FORBIDDEN
1
1
2
max
FIG.22 FIG.23
• Reducer oil level:
check the visible level control device (FIG.23-REF.1) and top-up if necessary (FIG.23-REF.2) with ELF POLYTELIS 100 or
equivalent.
• Check that the emergency buttons are not inserted.
• Lubrication water:
check that the lubrication water tray of the piston is full.
Restore the level by adding clean water through the mouth (FIG.24-REF.1) situated above the cylinder itself.
In winter add anti-freeze to prevent the formation of ice or discharge the water at the end of the shift.
The water must be replaced every 5 working days.
1
1
2
FIG.24 FIG.25