CAUTION! Always keep the nozzle in contact with the container being lled during the lling process to
minimize the possibility of static electricity build up.
1. If so equipped, reset Meter to “0” (do not reset while in use as
this can cause damage to the meter).
2. Remove dispensing nozzle from nozzle boot.
3. Move the switch lever to the “ON” (raised) position to start the
motor (gure 5). The pump should start and settle into a slow
idle.
4. Insert the dispensing nozzle into the container to be lled.
5. Operate the nozzle to dispense uid; release nozzle when the
desired amount of uid has been dispensed.
6. Move switch lever to the “OFF” (lowered) position (Figure
6) to stop the motor.
7. Remove the dispensing nozzle from the container being
lled and store it in the nozzle boot.
WARNING! Use caution when operating the pump. The hoses and electrical power cable can be a trip
hazard; caution should be exercised while moving around the hoses and power cable connected to avoid
tripping or entanglement.
Operational Safety
WARNING! NEVER disconnect the power cable from the pump while pump is switched on or connected to a
power source. ALWAYS switch the pump off and disconnect all the clamps from the power source PRIOR
to disconnecting the power cable from the pump. Electrical shorts, sparks, or unexpected start up can occur.
DANGER! DO NOT use pump in enclosed areas when pumping hazardous or explosive uids. Pumping
area should be well ventilated. Concentrated vapors in an enclosed area are noxious and highly explosive!
WARNING! Pump assembly can become hot with extended use. Use caution if you have to touch the pump
after extended periods of use.
CAUTION! DO NOT operate the pump if any part of the explosion proof motor construction is missing or
compromised. Disassembly of the motor will compromise the explosion proof design and void any warranty.
Figure 5
Figure 6
Switch “ON”
Switch “OFF”
IMPORTANT! The motor has power at all times when connected to a power source. The switch does
not apply or interupt power to the motor. High voltage may still be present inside the pump after power is
removed.