7. TECHNICAL SPECIFICATIONS
The specifications apply when the LCR meter is powered on for at least 30 minutes under regulated temperature.
Model
10kHz
30kHz
200kHz
Measurement function
Test parameter
| Z|, |Y|, C, L, X, B, R, G, D, Q, θ
Test signal frequency
10k Hz: 100Hz,120Hz,1kHz,10kHz
30kHz: 100Hz,120Hz,1kHz,10kHz, 20kHz, 30kHz
200kHz: 40Hz, 50Hz, 60Hz, 75Hz, 100Hz, 120Hz, 150Hz, 200Hz, 250Hz, 300Hz, 400Hz,
500Hz, 600Hz, 750Hz, 800Hz, 1kHz, 1.5kHz, 2kHz, 2.5kHz, 3kHz, 4kHz, 5kHz, 6kHz, 7.5kHz,
10kHz, 12kHz, 15kHz, 15.7kHz, 16.2kHz, 20kHz, 25kHz, 30kHz, 40kHz, 50kHz, 60kHz,
66.6kHz, 75kHz, 100kHz, 120kHz, 150kHz, 200kHz (38 points)
Basic accuracy
0.15%
0.1%
0.1%
Equivalent circuit
Series, Parallel
Mathematical function
Absolute Deviation and Percentage Deviation
Range mode
Auto, Hold, Manual Selection
Trigger mode
Internal, Manual, External, BUS
Measurement speed
Fast: max.30, Medium: 10, Slow: 3 (times/second) (1kHz)
Average times
1-255
Delay time
0-60s, step 1ms
Calibration function
Open circuit, Short circuit, Load
Measurement terminal
5-terminal
Display mode
Direct, Δ, Δ%, V/I (monitoring test voltage and current)
Display
5 digit 4.3-in LCD display
Measurement signal
Output impedance
30Ω, 100Ω
Test level
0.1V, 0.3V, 1V
0.1V, 0.3V, 1V
0.05V~1V
Test level accuracy
5%
Measurement display range
|Z|, R, X
0.01m Ω - 99.999 MΩ
|Y|, G, B
0.0001 µS - 99.999 S
C
0.0001 pF - 9.9999 F
L
0.0001 µH - 999.99 H
D
0.0001 - 9.9999
Q
0.0001 - 99999
θ (DEG)
-179.99º -179.99 º
θ (RAD)
-3.14159 - 3.14159
Δ%
-999.99% - 999.99%
Comparator and interface
Comparator
N/A
5-bin comparator
Memory
100 sets memories for internal parameter settings storage/save
500 sets for U disk parameter settings storage/save
Standard interface
RS232, USB HOST
RS232, USB HOST,
HANDLER
General
Operating environment
C - 40°C, ≤80%RH
Power source
110/220V±10%, 47~63Hz
Power consumption
30VA
Accessories
4-terminal Kelvin test clip leads, RS232 cable, power cord, operation manual
Dimensions
265W*100H*340D mm
Weight
Approx.3.5kg
For the purpose of product improvement, specifications are subject to change without prior notice.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the twintex LCR Series and is the answer not in the manual?

twintex LCR Series Specifications

General IconGeneral
Brandtwintex
ModelLCR Series
CategoryMeasuring Instruments
LanguageEnglish