Product Specifications
Chapter 1 Product Specifications
Control and Indicating Equipment Specifica-
tions
Zone Configuration
• 36 zone types, 12 programmable zone attributes
• Zone configurations available: normally closed, single EOL and
DEOL supervised
• Hardwired zone expansion (fully supervised) available using the
Model PC5108 (eight Zone Expander Module)
• One zone input available on the keypads
• Wireless zone expansion (fully supervised) available using the
model RF5132 or TR5164 (operating at 433MHz)
• 2 independent partitions (Max.) available for PC1616
• 8 independent partitions (Max.) available for PC1808
• 4 independent partitions (Max.) available for PC1832
• 8 independent partitions (Max.) available for PC1864
• 8 separate keypads (Max.)
Access Codes
• Up to 97 access codes: 94 user (level 2), one system master code
(level 3), one installer code (level 3), and one maintenance code
• Programmable attributes for each user code (see User Guide for
details)
• 1,000,000 access code variations (using 6-digit codes)
• Duress codes derived from user codes +/- 1 digit are not allowed
Warning Device output
• Rated 12VDC, 700mA, supervised (EOL resistor shall be used)
• Programmable as steady, pulsed or temporal three (as per ISO 8201)
output
• Fire alarm notification has priority over burglary alarm notification
Memory
• CMOS EEPROM memory
• Retains programming and system status on AC or battery failure
• Data Retention: 20 years min.
Programmable Outputs (PGMs)
• Up to 14 programmable outputs (PGM) with 38 options
• PGM outputs are open collector type and switched to ground
• One high current (300mA) output with 2-wire smoke detector capa-
bility on the main control board (PGM2)
• Eight additional low current outputs (50mA) available using the
Model PC5208
• Four high current outputs (500mA) available using the Model
PC5204
Power Supply
• 1.7A regulated, supervised and integral to the control unit
• Type A as per EN50131-6 Standard
• Input ratings: 220V-240Vac, 50/60Hz, 200mA
• Transformer required, mounted in the same enclosure, permanently
connected
• Transformer secondary ratings: 16.5Vac, 40VA min
• AUX Output Voltage: 12V
DC, -15%/+10% when AC Input Voltage is
85% to +110% of rated value and output current is 0.0A - 0.5A max.
• Output ripple voltage: 270mVp-p max.
• Storage device: Rechargeable battery, rated 12VDC
• Battery capacity: 4Ah, 7Ah, 14Ah (2 x 7Ah) or 24 Ah (2 x 12Ah)
• Maximum standby time 24Ah (when using 14Ah battery capacity
and AUX current limited to 480mA max.). Refer to Installation, Sec-
tion 8 Battery
• Recharging time 48h
• Programmable recharging current: Low 400mA, High 700mA
• Low battery trouble indication threshold 11.1V
DC
• Battery deep discharge protection (cut-off at 9.5VDC)
• Main board current draw: 85mA (set and unset state)
• Resettable fuses (PTC) used on circuit board instead of replaceable
fuses
• Supervision for loss of primary power source (AC Fail), battery fail
or battery low voltage (Battery Trouble) with indication provided on
the keypad
• Internal clock locked to AC power frequency
Operating Environmental Conditions
• Temperature range: -10°C to +55°C
• Relative humidity: 93% non condensing
Keypad Specifications
• Each keypad has 5 fully programmable function keys (see Section
[000] in the programming section.
• “T” version keypads have tamper protection
Alarm Transmitter Equipment (ATE) Specifica-
tion
• Digital dialer integral to the main control board
• Supports all major formats: SIA, Contact ID, 20BPS and Residential
Dial
• Complies with TS103 021-1, -2, -3 Telecom equipment require-
ments
System Supervision Features
The PC1616/PC1808/PC1832/PC1864 continuously monitors a number of
possible trouble conditions and provides audible and visual indication at the
keypad. Multiple signals are indicated using scroll buttons on the LCD key-
pads (no priority assigned) or by different lights on the LED’s keypads. Trou-
ble Conditions include:
Additional Features
• Automatic inhibit (swinger shutdown) for Alarm, Tamper, Trouble
signals after 3 occurrences in a given set period (see section [377]),
Opt [1] alarms, [2] tampers, [3] troubles.
• Programmable keypad lockout option (see section [012])
• 500 Event Buffer, date and time stamped
Enclosures
The PC1616/PC1808/PC1832/PC1864 main board can be installed in the
metal enclosures listed below: Tamper protection switches can be installed on
all enclosures, including door opening protection and/or removal from the
mounting position. Doors can be secured using screws or keylock.
• Model PC5003C (removable door) made of 22Ga steel, painted,
dimensions: 248mm(L) x 298mm(W) x 76mm(H), weight: 1500g.
• Model Power UC1 made of 18Ga steel, painted, dimensions:
315mm(L) x 319mm(W) x 100mm(H), weight: 3150g.
• AC Power Failure
• Trouble by Zone
• Fire Trouble
• Telephone Line Trouble
• Low Battery Condition
• Bell Output Trouble
•RF Jam
• Loss of Internal Clock
• AUX Power Supply Fault
• Tamper by Zone
• Failure to Communicate
• Module Fault (Supervisory
or Tamper)