9
User Commands
Press [][6] followed by the Master Code, then press the number corresponding to the following functions.
Additional Alphanumeric Keypad Functions:
When scrolling through the list of available functions, the following additional functions are available:
Event Buffer: Used to view the 500-event panel buffer
Brightness Control: Used to adjust the display back lighting level for optimal viewing
Contrast Control: Used to adjust the display contrast level for optimal viewing
Buzzer Control: Used to adjust the keypad buzzer tone for optimal sound
[][7][x] – Command Output (1-4)
Press [][7][x]. If the Command Output Code Required option is enabled, enter a valid user code. The panel will activate any PGM output assigned to
the command output.
[][8] – Installer Programming
Press [][8] followed by the Installer Code to enter Installer Programming. Refer to the ‘How to Program’ section for more information.
[][9][User Code] – No-Entry Arming
Press [][9] followed by a valid user code. The system will arm in the Stay mode and after the exit delay expires, it will remove entry delay. All zones
programmed as Delay will function like Instant zones. The system will flash the Armed light to indicate that the system is armed with no entry delay.
[][0] – Quick Arm/Quick Exit
Quick Arm: When disarmed, press [][0] to arm the system. The system will arm as if a valid user code was entered.
Quick Exit: When armed, press [
][0] to activate Quick Exit. The system will allow a single zone programmed as Delay to be violated once during the
following 2 minute time period without changing the status of the system.
3.5 Function Keys
Keypads have 5 programmable one-touch function buttons located in a column down the right-side of the keypad. These buttons can also be activated by
pressing and holding number [1] through [5] respectively for 2 seconds. The default for these function buttons on the PK series keypads are as follows:
[1] Stay Arm
[2] Away Arm
[3] Chime Enable/Disable
[4] Fire Reset – Command Output 2
[5] Quick Exit
[1]
Program Time and Date: Enter the time and date using the following format [HH:MM] [MM/DD/YY]. Program the time using military
standard (e.g., 8:00 pm = 20:00 hours).
[2]
Auto-arm/Auto-disarm Enable/Disable: The keypad will emit 3 rapid beeps if the Auto-arm/Auto-disarm feature is now enabled and a
steady 2-second tone if it is now disabled.
[3]
Auto-arm Time/Day: Press the number corresponding to the day of the week (1=Sunday, 2=Monday etc.) followed by the auto- arm time
(HH:MM). Program the time using military standard (e.g., 8:00 pm = 20:00 hours).
[4]
System Test: The panel will perform the following; activate the bell output, keypad buzzer and all keypad status lights for 2 seconds, test
the backup battery and transmit a reporting code to the central station (if programmed).
[5]
Enable DLS: The panel will temporarily enable DLS for 1 or 6 hours depending on programming (see section [702] opt.[7]).
[6]
User Initiated DLS: The panel will attempt to call the DLS computer.
[7]
For Future Use
[8]
For Future Use
For LCD Keypads: Scroll to the desired option then press []