PowerSeries - PC1616/PC1808/PC1832/PC1864
Chapter 5 Programming Descriptions
The following is a brief description of the features and options available in the PC1616/PC1808/1832/1864 control panel.
Global Stay Arming
If enabled by the installer, when this function key is pressed the panel will prompt the user for an access code. The panel will arm all parti-
tions assigned to that access code in Stay Mode when exit delay expires. If a partition was armed in Away mode when the Global Stay Arming
key is pressed, that partition will switch armed status to Stay when the delay expires. The Force arm attribute must be enabled on Entry/Exit
points for this feature.
Global Away Arming
If enabled by the installer, when hen this function key is pressed the panel will prompt the user for an access code. The panel will arm all parti-
tions assigned to that access code in Away Mode when exit delay expires. If a partition was armed in Stay mode when the Global Away Arming
key is pressed, that partition will switch armed status to Away when the delay expires. The Force arm attribute must be enabled on Entry/Exit
points for this feature.
Global Disarming
If enabled by the installer, when this function key is pressed the panel will prompt the user for an access code. The panel will then disarm all
partitions assigned to that access code.
Section [001] to [004] Zone Definitions
Option
Description
[00]
Null Zone: Zone not used
[01]
Delay 1: When armed, provides entry delay when violated (follows Entry Delay 1)
[02]
Delay 2: When armed, provides entry delay when violated (follows Entry Delay 2)
[03]
Instant: When armed, instant alarm when violated
[04]
Interior: When armed, instant alarm if the zone is violated first, will follow entry delay if entry delay is active
[05]
Interior Stay/Away: Similar to ‘Interior’ except panel will auto-bypass the zone if Armed in the Stay mode
[06]
Delay Stay/Away: Similar to ‘Delay 1’ except panel will auto-bypass the zone if Armed in the Stay mode
[07]
Delayed 24-Hour Fire (Hardwire): Instant audible alarm when violated, communication delayed 30 seconds - if alarm acknowledged
during this time (by pressing a key), the alarm will be silenced 90 seconds and repeat cycle - if not, alarm will latch and communicate after
30 second delay
[08]
Standard 24-Hour Fire (Hardwire): Instant alarm and communication when violated
[09]
24-Hour Supervision (Hardwire): Instant alarm and communication when violated. Will not sound the bell or keypad buzzer.
[10]
24-Hour Supervisory Buzzer: Instant alarm, panel will activate keypad buzzer instead of bell output
[11]
24-Hour Burglary: Instant alarm when violated, audible alarm at default. Reporting code BA, BH
[12]
24-Hour Hold-Up: Instant alarm when violated, silent alarm at default. Reporting code HA, HH
[13]
24-Hour Gas: Instant alarm when violated, audible alarm at default. Reporting code GA, GH
[14]
24-Hour Heat: Instant alarm when violated, audible alarm at default (also known as high-temp). Reporting code KA, KH
[15]
24-Hour Auxiliary (Medical): Instant alarm when violated, silent alarm at default. Reporting code MA, MH
[16]
24-Hour Panic: Instant alarm when violated, audible alarm at default. Reporting code PA, PH
[17]
24-Hour Emergency: Instant alarm when violated, audible alarm at default. Reporting code QA, QH
[18]
24-Hour Sprinkler: Instant alarm when violated, audible alarm at default. Reporting code SA, SH
[19]
24-Hour Water: Instant alarm when violated, audible alarm at default (also known as high water level). Reporting code WA, WH
[20]
24-Hour Freeze: Instant alarm when violated, audible alarm at default (also known as low-temp). Reporting code ZA, ZH
[21]
24-Hour Latching Tamper: Instant alarm when violated, panel cannot be armed until Installer Programming is entered
[22]
Momentary Keyswitch Arm: Arm or disarm the system when violated
[23]
Maintained Keyswitch Arm: Arm system when violated, disarm system when restored
[24]
For Future Use
[25]
Interior/Delay: Zone functions like an Interior zone when armed in Away mode, like a Delay zone when armed in the Stay mode
[26]
24-Hour Non-Alarm: Zone will NOT create an alarm. Can be used with zone follower function for automation applications
[29]
Auto-Verified Fire: When violated, system will reset all smoke detectors for 20 seconds, then wait 10 seconds for detectors to settle. If
another fire alarm detected within 60 seconds zone will go into alarm immediately
[30]
Fire Supervisory: Instant alarm, system will activate keypad buzzer. A valid user code is required to silence Keypad buzzer.