PowerSeries - PC1616/PC1808/PC1832/PC1864
44
[343] Code 17 Code 18 Code 19 Code 20 Code 21 Code 22 Code 23 Code 24
I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I
Code 25 Code 26 Code 27 Code 28 Code 29 Code 30 Code 31 Code 32
I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I
[344] Miscellaneous Opening (Disarming) Reporting Codes
I_______I_______I
For Future Use
I_______I_______I
For Future Use
I_______I_______I
For Future Use
I_______I_______I
For Future Use
I_______I_______I
For Future Use
I_______I_______I
Auto Arm Cancellation/Postpone
I_______I_______I
Special Opening
[345] Maintenance Alarm Reporting Codes [346] Maintenance Restoral Reporting Codes
I_______I_______I
Battery Trouble Alarm
I_______I_______I
Battery Trouble Restoral
I_______I_______I
AC Failure Trouble Alarm
I_______I_______I
AC Failure Trouble Restoral
I_______I_______I
Bell Circuit Trouble Alarm
I_______I_______I
Bell Circuit Trouble Restoral
I_______I_______I
Fire Trouble Alarm
I_______I_______I
Fire Trouble Restoral
I_______I_______I
Auxiliary Power Supply Trouble Alarm
I_______I_______I
Auxiliary Power Supply Trouble Restoral
I_______I_______I
TLM Trouble Code
I_______I_______I
TLM Restoral
I_______I_______I
General System Trouble
I_______I_______I
General System Trouble Restoral
I_______I_______I
General System Supervisory
I_______I_______I
General System Supervisory Restoral
I_______I_______I
For Future Use
I_______I_______I
Cold Start
[347] Miscellaneous Maintenance Reporting Codes [348] Test Transmission Reporting Codes
I_______I_______I
Telephone Number 1 FTC Restore
I_______I_______I
Walk Test End
I_______I_______I
Telephone Number 2 FTC Restore
I_______I_______I
Walk Begin
I___0__I___0__I
Event Buffer 75% Full Since Last Upload
I_______I_______I
Periodic Test Transmission with Trouble
I_______I_______I
DLS Lead IN
I_______I_______I
Periodic Test Transmission
I_______I_______I
DLS Lead OUT
I_______I_______I
System Test
I_______I_______I
Zone Fault Alarm
I_______I_______I
For Future Use
I_______I_______I
Zone Fault Restore
I_______I_______I
Delinquency Code
I_______I_______I
General Zone Low Battery Alarm
I_______I_______I
General Zone Low Battery Restoral
I_______I_______I
Installer Lead Out
I_______I_______I
Installer Lead In
[350] Communicator Format Options
Default
03 I_______I_______I 1st Telephone Number
03
I_______I_______I 2nd Telephone Number
01 20 BPS, 1400 HZ handshake 05 Pager 08 10 BPS, 2300Hz handshake 11 For Future Use
02 20 BPS, 2300 HZ handshake 06 Residential Dial** 09 For Future Use 12 For Future Use
03 DTMF CONTACT ID 07 10 BPS, 1400Hz handshake 10 For Future Use 13 For Future Use
04 SIA FSK **Failure to communicate using Residential Dial will not generate a Failed To Communicate Trouble.