15 ERP values
Technical information sheet Ubiflux Vigor W325 (Plus) in accordance with Ecodesign (ErP), no. 1254/2014 (Annex
IV)
Manufacturer: Ubbink NV
Model: Ubiflux Vigor W325 Plus
Climate
zone
Type of control SEC Value in
kWh/m²/a
SEC
Class
Annual
electricity
consumption
(AEC) in kWh
Annual heating
saved (AHS) in
kWh
Average manual -40.99 A 233 4614
clock control -41.59 A 215 4628
1x sensor (RV/CO
2
/VOC)
-42.72 A+ 181 4657
2 or more sensors (RV/CO
2
/VOC)
-44.71 A+ 124 4714
Cold manual -79.74 A+ 770 9026
clock control -80.48 A+ 752 9054
1x sensor (RV/CO
2
/VOC)
-81.88 A+ 718 9110
2 or more sensors (RV/CO
2
/VOC)
-84.42 A+ 661 9222
Hot manual -16.17 E 188 2086
clock control -16.69 E 170 2093
1x sensor (RV/CO
2
/VOC)
-17.66 E 136 2106
2 or more sensors (RV/CO
2
/VOC)
-19.33 E 79 2132
Type of venlaon unit: Balanced residenal venlaon appliance with heat recovery
Fan: EC - fan with innitely variable control
Type of heat exchanger: Recuperave plasc cross-counterow heat exchanger
Thermal eciency 91%
Maximum ow rate: 325m³/h
Maximum rated power: 145 W
Sound power level Lwa: 41 dB(A)
Reference ow rate: 228m³/h
Reference pressure: 50 Pa
Specic Power Input (SEL): 0.15 Wh/m³
Control factor: 1.0 in combinaon with mulple switch
0.95 in combinaon with clock control
0.85 in combinaon with 1 sensor
0.65 in combinaon with 2 or more sensors
Leakage* Internal 2.85%
External 2.85%
Posion dirty lter indicaon: On the display of the appliance / on the mulple switch (LED) /
on the Air Control.
Attention! For opmal energy eciency and a proper
operaon, a regular lter inspecon, cleaning or replacement is
necessary.
Internet address for Assembly instrucons: hp://www.ubbink.be
Bypass: Yes, 100% Bypass
* Measurements executed by TZWL according to the EN 13141-7 standard
Ubiflux Vigor W325 615743-G Ubbink / 57