43
Error messages
This is the complete list of error messages that can show up on the Ultimaker 3. For more information on troubleshooting
these error messages please go to the error specific page on the Ultimaker website.
Error - Stopped Temp Sensor
(ultimaker.com/ER01)
This refers to a problem with the PT100 B sensor, which is the sensor that
measures the temperature of the nozzle. It means that the sensor registers
incorrect values and due to safety reasons it will prevent the nozzle from heating
up. The most likely reason for this is connection problem, which could either
happen due to a bad connection at the main board or damage of the sensor itself.
Error - Stopped Temp Sensor BED
(ultimaker.com/ER02)
This error refers to a problem with the sensor of the heated bed. It means that
the sensor registers incorrect values and due to safety reasons it will prevent
the heated bed from heating up. The most likely reason for this is connection
problem, which could happen due to a bad connection on the heated bed or main
board, or damage of the sensor itself.
Error - Heater Error
(ultimaker.com/ER03)
The heater error can appear when the sensor doesn’t register a steady (increase
in) temperature. This could mean that the heater cartridge is not connected
properly and to prevent overheating of the nozzle it will therefore turn the heater
cartridge off.
Z-Switch Broken or Z-Switch Stuck
(ultimaker.com/ER05)
If you get one of these errors it means that there is a problem with the Z limit
switch. It either tells you that the Z limit switch can’t be pressed or that something
is preventing the lever of the switch from switching back.
X or Y Switch Broken
(ultimaker.com/ER07)
This error occurs when either the X or Y limit switch is not activated while the
print head is homing.