Specifications
A. General Specifications:
Maximum Voltage between any Terminals and grounding: Refer to different range
input protection voltage.
Display: 3 5/6 digits LCD display, Maximum display 6666.
Polarity: Auto
Overloading: Display OL or –OL.
Battery Deficiency: Display .
Sampling: 3 times per second.
Measurement Deviation: The conductor being meaured is not placed in the center
of the jaw during AC/DC current measurement, it will cause extra 1% deviation
based on the stated accuracy.
Drop Test: 1 meter drop test passed.
Max. Jaw Size: 55mm diameter.
Projected Max. Current conductor size: 45mm diameter.
Electro-Magnetic: When carrying out measurement near the electro-magnetic, it
may cause unstable or wrong reading.
Power: 1 x 9V battery (6LF22 1604A)