Non sine wave must follow the below data to adjust:
Peak factor: 1.4~2.0, add 1.0% on the stated accuracy.
Peak factor: 2.0~2.5, add 2.5% on the stated accuracy
Peak factor: 2.5~3.0, add 4.0% on the stated accuracy.
J. Temperature (UT208 only)
Range
40
~1000
-40 ~1832
Resolution
1
1
Overload protection
250VAC
Accuracy
-40 ~0 : (3%+4)
0 ~400 : (1%+3)
400 ~1000 :
(2%+10)
-40
~32 : (3%+8)
32
~752 : (1%+6)
752
~1832 :
(2%+18)