67
Model UT71A/B/C/D/E: OPERATING MANUAL
Remarks:
l
Input amplitude "a" as follows; (DC electric level is zero)
When 10Hz~40MHz : 200mV a 30Vrms;
When > 40MHz : Not specified
I. Frequency
Range
Resolution
Accuracy
Overload Protection
40Hz
400Hz
4kHz
40kHz
400kHz
4MHz
40MHz
400MHz
1000V
(0.01%+8)
Not Specified
UT71C/D/EUT71A/BUT71C/D/EUT71A/B
20Hz
200Hz
2kHz
20kHz
200kHz
2MHz
20MHz
200MHz
(0.1%+15)
Not Specified
0.001Hz
0.01Hz
0.0001kHz
0.001kHz
0.01kHz
0.0001MHz
0.001MHz
0.01MHz

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT71A and is the answer not in the manual?

UNI-T UT71A Specifications

General IconGeneral
Data holdYes
Product typeDigital multimeter
Frequency range0.02 - 200000 kHz
AC current range0.2 - 10 A
AC voltage range2 - 1000 V
DC voltage range0.2 - 1000 V
Capacitance range20 - 20000 nF
Statistic functionMaximum, Minimum
Basic accuracy (frequency)0.1%+15
Basic accuracy (DC current)0.2%+20
Basic accuracy (DC voltage)0.1%+8
Basic accuracy (resistance)0.5%+20
Basic accuracy (capacitance)1.5%+20
Dimensions (WxDxH)93 x 40 x 200 mm
Battery voltage9 V
Weight and Dimensions IconWeight and Dimensions
Weight384 g