P13
1
-
+13V
Bridge board connection
(CANBUS)
2 B
3 A
4 GND
P28 AMP Modu II 6P
1
-
Potential free contact 1
2 GND
3 Potential free contact 2
4 GND
5 Potential free contact 3
6 GND
2
P14 CPM-5P-3P81
1
MultiPoint
IN1
Multi point core probe input
2 IN2
3 IN3
4 IN4
5 GND
P15 AMP Modu II 2P
1
- Single point core probe input
2
P16 JST XHP-2
1
CMB2
IN
Top temperature probe
2 GND
P17 MINIFIT 2P
1
DOOR1
IN
Door switch 1 input
2 GND
P18 MINIFIT 2P
1
DOOR2
IN
2 GND
P19 JST XHP-2
1
CMB1
IN
Bottor temperature probe
2 GND
P20 AMP Modu II 4P
1
TAC1/2
+13V
Tachometer input TAC1 e
TAC2
2 IN_TAC1
3 IN_TAC2
4 GND
P30 AMP Modu II 4P
1
TAC3/4
+13V
Tachometer input TAC3 e
TAC4
2 IN_TAC3
3 IN_TAC4
4 GND
P21
1
21VAC
21V ac
21 V AC power supply from
secondary transformer
2 21V ac
3
12VAC
12V ac
12 V AC power supply from
secondary transformer
4 12V ac
P22
INARLOCK 5P 1F
(Black)
1 TL1
High-Power contactor phase
2 N
TL1 and TL2 neutral
3 TL2
Low-Power contactor phase
4 TSA
Safety thermostat output
5 TSR
Safety thermostat return
Door switch 2 input (only
used in trolley ovens)
MOLEX Microfit 4P
MOLEX Minifit 4P