ELECTRICAL POWER
The electrical installation must be per-
formed by a qualified electrician in accordance
with all applicable electrical codes. Refer to
Figure 17, and proceed as follows:
1. Connect the outside power source to
the terminals on top of the disconnect in
the starter enclosure. The hazard alert
label on the front of the starter enclosure
specifies proper voltage for this machine.
To maintain the watertight feature of the
starter enclosure, use “liquid tight” or rigid
conduit and appropriate fittings at the
power source entry point on the side of the
starter enclosure.
NOTE: If voltage is not at least 95% of
specified voltage, the motor may become
overloaded during operation.
2. Connect ground conductor (green or
green and yellow striped wire) to the earth
termination point located on back panel
inside the starter enclosure.
3. Connect the wiring so the impeller turns
clockwise when viewed through the feed
opening.
4. Securely fasten screws on the starter
enclosure door when finished with installa-
tion.