MOTOR OVERLOAD
If the motor shuts off during operation, it is
likely that it has been overloaded. After main-
tenance personnel have corrected the prob-
lem (allowing at least five minutes for thermal
overloads to cool) machine may be restarted
by first pressing the “RESET” button on the
starter enclosure then starting in the normal
manner. If motor again shuts off, see
“Troubleshooting”, page 64.
OPERATION
Machine Overload or Jam
26
CORRECTING MACHINE OVERLOAD OR JAM
DANGER: Never try to remove jammed product
while the machine is running! You may come into
contact with cutting parts which could cause severe
injury!
1. Push “O” (STOP) button then disconnect and lock out power source.
2. Only qualified trained personnel should proceed to step 3.
3. Remove or open guards to expose jammed area and visually verify that all parts have
stopped.
4. Remove the obstruction. Keep hands away from cutting parts.
5. Remove all product from the feed area and replace or close all covers and guards.
6. Machine is ready to restart and resume feeding product. If proper feeding procedures are
followed, product will flow evenly into feed areas.
CAUTION: If product continues to jam in the feed or discharge areas, DO NOT
operate the machine. Contact your supervisor.
DANGER!